Support: +91 484 405 0332

Home Automation Components

Installer Programming Ethernet Port, DIN-Rail Mount, (Bus and Ethernet Interface),Can Be used Dual: (For Programming + As Network Bridge)

Parameters
Power Input: DC 8-32V DC from Bus
Power Consumption: 20mA/DC24V
Working Temperature: 0℃~+45℃
Working Relative Humidity: 20% - 90%
Storage Temperature: -40℃- +55℃
Storage Relative Humidity: 10% - 93%
Installation: Standard 35mm rail mounting
Communication: HDL-BUS

Function
Switch function:Bi-directional data interchange between HDL-BUS and Ethernet
Soft reset function that reset IP to default
Remote management
Intelligent data interchange, to minimize the data flux
Powered by bus , small size good for programming kit
LED Ethernet connection indicator

Small, Elegant and Powerful Relay Each is 2 ch Pass Through, Switch Over Relays 5A, Green operated supplied by 24VAC/25mA from bus, For Any Motor 2 direction operation like: Curtain, Drape, Screens, Gates, Lift, Escalator, Plasma Lifts, Sky Lights, Pool covers etc.

Parameters
Power Supply: DC24V
BUS Power Consumption: 35mA/DC24V
Working Condition:
Working Temperature: 0℃~45℃
Working Relative Humidity: 20%~90%
Storage Temperature: -40℃~+55℃
Storage Relative Humidity: 10%~93%
Controllable Curtain: 2 curtains can be controlled
Motor Type: Capacitive Single phase
Maximum Current in each channel : 5A
Life time for Relay unit: More than 60,000 times
Installation: Standard 35 mm Din Rail

Function
2 channel for curtain control
Modes: Forward, Backward and Stop
Delay time for Forward and Backward is available

Advanced Technology Module that install near the unit itself to save the cost of long wiring to the ordinary Thermostat and replace the ugly thermostat in the wall, it is bus enabled and controlled by the SB-DLP panel that have built in temp sensor and Air condition control. The Air condition Module can control Single and Multi stage Units (Heat, Cool, Fan low, High, Medium, VAV 0-10VDC) that Handle FCU, AHU, VAV Systems.

Parameters
Power Input: DC 8-32V DC from Bus
Power Consumption: 35mA /DC24V
Output channels: Relay 5A, 1 output 0-10 VDC
Working Temperature: 0℃~+45℃
Working Relative Humidity: 20% - 90%
Storage Temperature: -40℃- +55℃
Storage relative humidity: 10% - 93%
Installation: Standard 35mm rail mounting
Communication: HDL-BUS

Function
5 channel output: 5A Relay
All Compressor and fan power 24VAC, 110VAC, 220VAC can be connected to the 5A pass throw Relay
Fan speed: high, middle low
Mode: Cooling, heating, Humidifier , dehumidifier
Control Single or multi stage compressor.
Safety Compressor running sequence.
Safety operation ON, OFF for compressors and fans
Analog fan interface VAV can be set from 0-10V DC depend on fan speed
Bus enabled that save your wiring of normal thermostat.

Z-Audio Music distributed Multiroom streaming Media Box with Amplifier 50Watts, Built in RDS Radio tuner, 1 Local Source, LAN/TCP/IP Port, Antenna Port,Intercom Mic Input Port, 1SD Card Port, With Base Digital Adjustment. ((2 Extra Internal Ports/Slot for Optional Add on Dhauter Boards)) HDL-BUS and FTP/IP Enabled.

Parameters
Working Voltage: DC±24V/2A
Static Power Consumption: 94mA/DC+24V. 61mA/DC-24v
Signal Interface: HDL-BUS; RJ45; SD Card; RCA Audio; Audio output; 3 ports Power input
Audible frequency Input: 1.25db/Step
Audible frequency Output: RL=8, RR=8 THD=10% VP=25V Power=50W
Music File Format: MP3
Communication Protocol: HDL-BUS, FTP Data Exchange Protocol, UDP
Volume of SD Card:£8G
Working Temprature: 0-40℃
Working Relative Humidity:20%-90%
Store Temprature:-40-+55℃
Store Relative Humidity: 10%-93%

Function
External Input
Internal SD card Play
FM Radio
FTP Music Server
RS485 BUS Data Switch Function
6- RS485 BUS communication

12CH 10A High Power Relay Module, DIN-Rail Mount, with fast connection, 10A per Channel,with scene and sequence controller, for DC, single and three phase power, up to 440VAC

Parameters
Power supply:DC24V
Static BUS Power Consumption:15mA/DC24V
Dynamic BUS Power Consumption: 40mA/DC24V
Working condition
Working Temp:0~45℃
Working Relative Humidity:20%~90%
Storage Temp:-40℃~+55℃
Storage relative Humidity:10%~93%
Current in each channel:10A
Life time for relay unit: more than 60,000 times
Protection:Need exterior protection switch
Installation: standard 35mm Din Rail
Capacity load of Relay: < 150μF

Function
12 channel relay output
Maximum12 separate areas,
Each area has 24 scenes, maximum runtime of scene: 60 minutes
Each area has 2 sequences, each sequence has 12 steps
Each channel has lights protection delay: 0-60 minutes
Each channel has switch on delay time: 0-25 seconds
Manual switch is available for each channel
Remote program and management are available
Can go back to previous scene or designated scene once the system restart
LED lights available for indicates of each channel
Stair lamps function and Mutual exclusion function
Support simple programming model
Support HDL-BUS Upgrading

8CH 10A High Power Relay Module, DIN-Rail Mount, with fast connection, 10A per Channel,with scene and sequence controller, for DC, single and three phase power, up to 440VAC

Parameters
Power supply:DC24V
Static BUS Power Consumption:15mA/DC24V
Dynamic BUS Power Consumption: 40mA/DC24V
Working condition
Working Temp:0~45℃
Working Relative Humidity:20%~90%
Storage Temp:-40℃~+55℃
Storage relative Humidity:10%~93%
Current in each channel:10A
Life time for relay unit: more than 60,000 times
Protection:Need exterior protection switch
Installation: standard 35mm Din Rail
Capacity load of Relay: < 150μF

Function
8 channel relay output
Maximum 8 separate areas,
Each area has 16 scenes, maximum runtime of scene: 60 minutes
Each area has 2 sequences, each sequence has 12 steps
Each channel has lights protection delay: 0-60 minutes
Each channel has switch on delay time: 0-25 seconds
Manual switch is available for each channel
Remote program and management are available
Can go back to previous scene or designated scene once the system restart
LED lights available for indicates of each channel
Stair lamps function and Mutual exclusion function
Support simple programming model
Support HDL-BUS Upgrading

4CH 10A High Power Relay Module, DIN-Rail Mount, with fast connection, 10A per Channel,with scene and sequence controller, for DC, single and three phase power, up to 440VAC

Parameters
Working Voltage:DC24~30V
BUS Power Consumption :28mA@DC 24V
Relay: 50A Magnetic latching relay
Output channel:4CH/16A
Max current in each channel:16A
Electronic life time for relay: > 60000 (Resistance Load)
Protection:Connect a breaker in each channel
Protection Degree: IP20

Function
4 channel Relay output unit
Scene controller function available
Up to 4 separate area
Each area has 8 scenes, maximum running time for scene is 60 minutes
Each channel has light protection delay (0-60 minutes)
Each channel has batch turn-on delay(0-25 seconds)
Each channel has manual control for relay unit
It is optional setting of choosing a designated scene or back to previous scene when power on again after power off
Communication: HDL Bus

HDL-MD0602.432, 6 channel 2A Dimmer,supports AC240V and AC110V power input. It has 6 output channels, each channel has a bypass button for manual control. There is a fuse protection for each channel, the Dimmer will be protected in case of short circuit. LED indicator will show you which channel has short circuit.

Parameters
Working Voltage:DC15~30V
Power Consumption :28mA@DC 24V
Output channel :6CH/2A
Fuse:4A aR type
TRIAC:16A TRIAC,Minimum Load 40w
Dimming curves: Linear 、1.5 exponent、2.0 exponent,3.0 exponent
Dimension:144mm×90mm×66mm
Certification:CE
Protection Degree: IP20
Working Temperature:0~45℃
Working relative Humidity: 20%~90%
Storage Temperature: -40℃~+55℃
Storage relative Humidity: 10%~93%

Function
Up to 6 separate Areas and max 12 scenes for each area
Up to 6 sequences and each sequence has 12 steps
4 Dimming curves, the dimming accuracy is 512 step
Low, high , max threshold for each channel
Bypass button for manual control available for each channel
It is optional setting of choosing a designated scene or back to previous scene when power on again after power off
Short circuit and over heat protection
Max 2A of each channel,4A fuse of each channel for protection(aR type)
Support HDL-Bus Pro online upgrading and Easy program mode

HDL-MD0403.432, 4 channel 3A Dimmer,supports AC240V and AC110V power input. It has 2 output channels, each channel has a bypass button for manual control. There is a fuse protection for each channel, the Dimmer will be protected in case of short circuit. LED indicator will show you which channel has short circuit.

Parameters
Working Voltage:DC15~30V
Power Consumption :28mA@DC 24V
Output channel :4CH/3A
Fuse:8A aR type
TRIAC:25A TRIAC,Minimum Load 40w
Dimming curves: Linear 、1.5 exponent、2.0 exponent,3.0 exponent
Dimension:144mm×90mm×66mm
Certification:CE
Protection Degree: IP20
Working Temperature:0~45℃
Working relative Humidity: 20%~90%
Storage Temperature: -40℃~+55℃
Storage relative Humidity: 10%~93%

Function
Up to 4 separate Areas and max 12 scenes for each area
Up to 6 sequences and each sequence has 12 steps
4 Dimming curves, the dimming accuracy is 512 step
Low, high , max threshold for each channel
Bypass button for manual control available for each channel
It is optional setting of choosing a designated scene or back to previous scene when power on again after power off
Short circuit and over heat protection
Max 3A of each channel,8A fuse of each channel for protection(aR type)
Support HDL-Bus Pro online upgrading and Easy program mode

HDL-MD0206.432, 2 channel 6A Dimmer,supports AC240V and AC110V power input. It has 2 output channels, each channel has a bypass button for manual control. There is a fuse protection for each channel, the Dimmer will be protected in case of short circuit. LED indicator will show you which channel has short circuit.

Parameters
Working Voltage:DC15~30V
Power Consumption :28mA@DC 24V
Output channel :2CH/6A
Fuse:12A aR type
TRIAC:25A TRIAC,Minimum Load 40w
Dimming curves: Linear 、1.5 exponent、2.0 exponent,3.0 exponent
Dimension:144mm×90mm×66mm
Certification:CE
Protection Degree: IP20
Working Temperature:0~45℃
Working relative Humidity: 20%~90%
Storage Temperature: -40℃~+55℃
Storage relative Humidity: 10%~93%

Function
Up to 2 separate Areas and max 12 scenes for each area
Up to 6 sequences and each sequence has 12 steps
4 Dimming curves, the dimming accuracy is 512 step
Low, high , max threshold for each channel
Bypass button for manual control available for each channel
It is optional setting of choosing a designated scene or back to previous scene when power on again after power off
Short circuit and over heat protection
Max 6A of each channel,12A fuse of each channel for protection(aR type)
Support HDL-Bus Pro online upgrading and Easy program mode

Pages